Furthermore it contains power system parameters whichĪre important for the test modules. Information about the substation and the feeder. The General Information block contains the parameters which are important for the test report, e.g.
Omicron test universe software 2.4 manual#
Have to be changed (except the General Information and Circuit Breaker Information block), as they areĪlready set to the values given in the user manual of the relay. All values set in this blockĬan be found in the chapter "Technical Data" of the relay's documentation. This block has been added for relay specific parameters such as tolerances or angles of directionalĮlements which cannot be set by the user, because they are constant values. Each parameter in this block can be identified by a Foreign ID, which is identical to theįigure 3: Setting the parameters in the Customer Input section The parameters are grouped and named as in the SiemensĭIGSI software. In this block, setting parameters are included. Parameters are included in this section and can be set to the actual relay values. The Customer Input section includes parameters which can be changed by the user. Template controller section can only be seen in the advanced view. The converter comes up in the standard view the RIOplus section and the

The converter is divided into two sections: the 7SA513 section and the RIO section. For detailed information, see the PTT Distance documentation. The OMICRON test strategy is described in the OMICRON Protection Test Template (PTT) Distanceĭocumentation. High-Resistance Ground Fault Protection in Solidly Ground Systems.Ground Fault Detection in Non-Grounded Systems.The following functions are currently not supported: 21 Distance starting (Overcurrent ''Always ON '', Impedance, and V/I/Phi Starting)įor testing the other functions, you must use LinkToXRIO.The following functions are using the RIO interface:

The test modules are configured automatically without using LinkToXRIO. The Siemens 7SA513 XRIO converter implements the following functions:įigure 2: Functional range of the Siemens 7SA513 XRIO converterįor some of the functions listed above use the RIO interface of the Test Universe software.
Omicron test universe software 2.4 license#
To use this converter, you must have a valid license for the OMICRON Test Universe 2.11 SR1 software. See sections 8.1 - 8.4 for more information about using the XRIO converter with the OMICRON LinkToXRIO or start using the relay specific test template (for more information, see the test template In any way the converter is used, follow the quick start instructions and create your test by using Relay specific test template, for example with the OMICRON Distance template for the 7SA513 relay. The Siemens 7SA513 XRIO converter can be used as a stand-alone converter or in association with a Insert +inf (infinity) to disable settings/functions, if necessary.įigure 1: Opening and importing the Siemens 7SA513 XRIO converter Enter all necessary settings in the Customer Input section (see section 8.1 ).ħ. Insert a new test object or open the existing test object.Ħ. Start a new OMICRON Control Center (OCC) document or open an existing OCC document.Ģ. To work with the Siemens 7SA513 XRIO converter:ġ. Note: This converter is tested with the relay described above. Testing the distance protection functions (see section 2 ) of the 7SA513 relays. The converter provides all necessary data for The Siemens 7SA513 XRIO converter is designed for testing Siemens 7SA513 distance protection relaysīy using the OMICRON Test Universe 2.11 software.

9Ĩ.3 Activating the RIO Functions.9Ĩ.4 Specific Features.10Ĩ.4.1 Distance Protection Controlled Zone Z1L. 7Ĩ.1.2.5 Overcurrent Protection Phase-Ground. 7Ĩ.1.2.4 Overcurrent Protection Phase-Phase. 6Ĩ.1.1.2 Helper Parameters/Template Controller (Advanced view). 5Ĩ.1 7SA513 Section.5Ĩ.1.1 Relay Parameter Section Block.5Ĩ.1.1.1 Additional Information. 4ĥ Functional Range.4Ħ Not Supported Functions.5ħ OMICRON Test Strategy.5Ĩ Converter Structure. 3ģ Using the Converter.4Ĥ Required Software Version. OMICRON PTL Siemens 7SA513 XRIO Converter User Manualġ General Information.3Ģ Quick Start Information. Xrio converter manual 7 sa513 v3.3 enu tu2.11 v1.000